AeroGCS GREEN
  • AeroGCS GREEN User Manual
  • 1. Introduction
  • 2. System Requirements
  • 3. Getting Started
    • 3.1 Installing AeroGCS GREEN
    • 3.2 Activating AeroGCS GREEN
    • 3.3 Updating AeroGCS GREEN
      • 1. Play Store Update: The Classic Method
      • 2. Inline Update: Update on the Go!
  • 4. Dashboard
  • 5. Home Menu
  • 6. Projects
    • 6.1 Create a New Project
      • 6.1.1 Automatic Flying Method
      • 6.1.2 Manual Flying Method
    • 6.2 Handling Existing Project
      • 6.2.1 Open existing project
      • 6.2.2. Edit a Plan
      • 6.2.3 View and Edit the Plan Report
      • 6.2.4. Edit a plot
      • 6.2.5 Add a plot to the existing project
      • 6.2.6 Download Plot and Plan
      • 6.2.7 Delete a Project
        • 1: Not Logged in to AeroGCS Enterprise
        • 2: Logged in to AeroGCS Enterprise
  • 7. Connecting a Drone
    • 7.1. Using Serial Port
    • 7.2 Using TCP
    • 7.3 Using UDP
    • 7.4. Using Bluetooth
    • 7.5 Using H12
    • 7.6 Drone Registration
  • 8. RPA Settings
    • 8.1 Aircraft Settings
    • 8.2 Spraying system:
      • 8.2.1 Spray testing
      • 8.2.2 Spraying Parameters
      • 8.2.3 Clear Trapped Air
      • 8.2.4 Set Spray Tank Level
      • 8.2.5 Empty Threshold Action
      • 8.2.6 Flow Meter Error Alert
      • 8.2.7 Calibrate Pump Flow
      • 8.2.8 Calibrate Flow Meter
      • 8.2.9 Restore flow Meter to Factory Setting
    • 8.3 Remote Controller Settings
      • 8.3.1. Radio calibration
      • 8.3.2. Channel Monitor
      • 8.3.3. Advance Settings
    • 8.4 Compass Calibration Settings
      • 8.4.1. Compass
      • 8.4.2. Large Vehicle Calibration:
    • 8.5 IMU Calibration Settings
      • 8.5.1 Accelerometer Calibration:
      • 8.5.2 Level Horizon Sensor Calibration
      • 8.5.3 Barometer Calibration:
    • 8.6 Camera Settings
    • 8.7 General Settings
    • 8.8 AeroMegh / Enterprise Account
      • 8.8.1. Login:
      • 8.8.2. Account Details
  • 9. Field Plotting
    • 9.1. RC/Mobile:
    • 9.2. Drone
    • 9.3. Map
    • 9.4. Import KML
  • 10. Mission Planning
    • 10.1 Parameters
    • 10.2 Adjust Waypoint
    • 10.3 Adjust Spacing
    • 10.4 Indentation
    • 10.5 Obstacle Boundary
    • 10.6 Route Adjust
    • 10.7 Move Plan
    • 10.8 Plan Splitting
  • 11. Obstacle Avoidance
    • 11.1 Polygon Type Obstacle
    • 11.2 Circle Type Obstacles
    • 11.3 Edit Obstacles
    • 11.4 Delete Obstacle
  • 12. Flyview
    • 12.1 Flight Controls
    • 12.2 Flight Details
    • 12.3 Spray Rate Dosage Calculation
    • 12.4 Status details and settings option
    • 12.5 Range Finder
    • 12.6 Notifications
    • 12.7 Arm and Disarm Navigation Bar
  • 13. Report Generation
    • 13.1. View Report
    • 13.2. Generate Field Report
  • 14. Managing data
  • 15. Creating AeroGCS Enterprise Account
  • 16. Troubleshooting
Powered by GitBook
On this page

Was this helpful?

  1. 8. RPA Settings
  2. 8.4 Compass Calibration Settings

8.4.1. Compass

Previous8.4 Compass Calibration SettingsNext8.4.2. Large Vehicle Calibration:

Last updated 6 months ago

Was this helpful?

To calibrate the compass, follow these steps:

Step 1. To calibrate the compass, access the screen by navigating to "Compass Calibration" in the settings menu. The following screen will be displayed on the user’s device.

Step 2. Click on the "Calibrate Compass" button and follow the on-screen instructions as demonstrated on the displayed screen on the user’s device.

Step 3. Click on the "Start" button to initiate the compass calibration process, and the following screen will be displayed.

Follow the on-screen instructions that appear to complete the compass calibration process.

Upon successful completion of the compass calibration, a message will be displayed, and the progress value will indicate 100%. Following this, the device will automatically reboot.

Compass calibration
Start compass calibration
Compass calibration process